YL9101 Vacuum Degasser

Number of channel: 4 CHs

Maximum flow rate: 10ml/min per channel

> 0-2.0ml/min per channel for 70% Gas Removed from Methanol

Internal volume per channel: 925ul per channel

Materials in contact with solvent: Teflon AF, PEEK and Glass-filled PTFE

Safety & maintenance: Error detection

Dimensions: 385 X 80 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection; 50/60Hz, ±5%, 20W

Home.
About.
Contact Us.
Services.
Catalogue.
Customized.
Newsletter.
FAQ.
Legal.
Free Downloads.
New products.

YL9110 Quaternary Pump

Operating principle: Parallel dual-plunger pump, Low-pressure gradient

Control mode: Constant flow, Constant pressure

Compressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : ≤1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi > Operating range: 0-6000 psi up to 5ml/min  > Operating range : 0-3000 psi up to 10ml/min

Pressure pulsation : ≤1% at 1ml/min

Number of eluent lines: 4

Gradient formation: 4-channel mixing valve

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection, 50/60Hz, ±5% , 70W

YL9111 Binary Pump

Operating principle: X 2 Parallel dual-plunger pump, High-pressure gradient

Flow range: 0.001-10ml/min

Number of eluent lines: 2

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 140W

 

.YL9112 Isocratic Pump

Operating principle: Parallel dual-plunger pumpCompressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : ≤1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi

> Operating range: 0-6000 psi up to 5ml/min

> Operating range: 0-3000 psi up to 10ml/min

Pressure pulsation : ≤1% at 1ml/min

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%,  50/60Hz, ±5%, 70W

 

YL9120 UV/Vis Detector

Wavelength Range: 190-900 nm

Data collection rate: up to 50Hz

Deuterium arc lamp & tungsten lamp

2-Order filter: Automatic filter switching

Bandwidth: 5.5 nm

Wavelength Accuracy : ±1 nm

Wavelength Precision : ±0.1nm

Linearity: >99.5% at 2.5 AU (acetone, 254nm)

Noise level : <±0.5 X 10^(-5) Abs/min , 254nm, dry cell

Drift : <1 X 10^(-4) Abs/hour

Dispersion element: Concave grating

Warm-up period: 1 hour

Flow Cell Design: Cone type

Path Length: 10 mm (Analytical cell)

Cell Volume: 10 uL (Analytical cell)

Pressure limit: 1500psi (Analytical cell)

Wetted materials: 316 stainless steel, Quartz, Teflon

Analog Outputs:  Two, software selectable: Absorbance Energy, Sample Energy, Reference Energy Communications: LAN

Power-up Diagnostics: Optics and electronic diagnostic routine

Power-up Wavelength Verification: Automatic on power up via internal holmium filter and D2 lamp

5-Point Wavelength Calibration: On demand via internal holmium filter and D2 lamp

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 100W

YL9160 PDA Detector

PDA  A/D Resolution: 16bit

Slit Bandwidth:  1.7nm  Pixel Resolution: 0.9nm Channel: 1024

Wavelength: 190~950

Shield Optics

Analytical Cell

     - Path-length: 10mm

     - Pressure       : >1500psi

     - Volume         : 13ul

Dimension:   W: 385mm  H: 160mm  D: 565mm

Weight:  15Kg

Noise Level: +/- 0.00002 AU (Empty Cell, 1sec Rise Time, 254nm)  

Drift  : 0.0002AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)

 

Wavelength Accuracy: <1nm (HY-1 Holmium Oxide Filter)

 

Sampling Rate: Max. 50Hz  1~16 nm Spectral Bandwidth, Wide Spectral Range, Alternative Spectral Function

 

GLP Compliance:

 - Photometric Accuracy, Linearity, Noise Level, Drift - System Check,

 

Analog Output: 2 channel (Replaceable Dual Wavelength Detector)      

Valve Output:  2ch, Programmable Sampling (Fraction Collector Function Available )

 

Trigger Input: 2ch

Communication: TCP/IP, RS232C

Simultaneous Data Channel:  8 or Full Scan

Filtering: Bessel, RC, Aver. 0.01~10Hz

YL9150 Autosampler (Alias)

Sound pressure level: LeAq < 70 dB

Working temperature: 10 - 40°C

Humidity: 20 - 80% RH

Safety and EMC compatibility: According to EC-directives; CSA (UL) approved

Power requirements: 95 - 240 Volt AC ± 10%; 50/60 Hz; 200VA

Sampling:

Sample capacity: 2 Micro Well Plates according to SBS standards; 96-well high/low

Loop volume: 1 - 5000 µL programmable, 10 mL loop optional

Dispenser syringe: 500 µL standard or 2500 µL for Prep option

Vial detection: Missing vial/well plate detection by sensor

Headspace pressure: Built-in compressor, but only for vials with septa

Switching time injection valve: Electrically < 100 msec

Piercing precision needle: ± 0.6mm

Wash solvent: External wash solvent bottle (bracket optional)

Wetted parts in flow path: SS316, PTFE (teflon), ETFE  (tefzel), VESPEL, PCTFE (Kel-F). Optional: PEEK

(10) Injection cycle time: < 60 sec. in all injection modes for 1 injection ≤ 100 µL including 300 µL wash / < 20 sec in partial loopfill mode for 1 injection of 10µL including 500 µL wash

Performance

Easy to use

Fast installation

 

What is your choice tomorrow ?

 

Contact us NOW for a quote

Our new ELSD is an essentially universal detector, primarily used in High Performance Liquid Chromatography (HPLC). Young Lin ELSD is an ideal substitute,or supplement to, traditional HPLC detectors for liquid chromatography concentration detection.

In comparison to other ELSD detectors, Young Lin ELSD has the ability to vary the split ratio smoothly over a wide range with a new patented (Patent No. US 7,290,723 B1) Thermo-Split Technology. This precise vapor phase control combines a gentle bend with a temperature controlled spray chamber.
This means that with one low cost detector you can handle high volume as well as difficult to evaporate mobile phases optimally, efficiently and easily, all without sacrificing sensitivity.

Features

Sensitive Detection for a Wide Variety of Chemical Classes and Structures

Patented Thermo-Split™ Technology for Precise Vapor Phase Control

(Patent No. US 7,290,723 B1)

A single multi-flow, nebulizer for use with micro-bore to semi-preparative flow rates.

Very low detector volume resulting in the smallest peak within 3 sec

Fast Start-up / Easy to Use

No Consumable Parts

Low Cost of Operation

There are 2 types of ELSD as below.

YL9180 ELSD

 

Display 2 Line x 20 Character per line VFD  

User Interface Two multi-function buttons Four multi-function buttons

Evaporative Zone Temp. 60°C Ambient to 120°C

Thermo-Split™ Chamber Temp. 30°C to 60°C  

Liquid Flow Rate 0.2mL/min to 3mL/min

Wetted Materials Stainless steel, glass, anodized aluminum, Teflon™  

Light Source 670 nm Laser Diode, <5mW  

Detector Hermetically sealed photo-diode/operational amplifier  

Interface RS232, Contact Closure  

Typical Laboratory General Laboratory Advanced Research

Sensitivity More Sensitive

 

 YL9181 ELSD

 

Display 2 Line x 20 Character per line VFD  

User Interface  Four multi-function buttons

Evaporative Zone Temp. 60°C Ambient to 120°C

Thermo-Split™ Chamber Temp. 10°C to 70°C

Liquid Flow Rate 0.2mL/min to 5mL/min

Wetted Materials Stainless steel, glass, anodized aluminum, Teflon™  

Light Source 670 nm Laser Diode, <5mW  

Detector Hermetically sealed photo-diode/operational amplifier  

Interface RS232, Contact Closure  

Typical Laboratory General Laboratory Advanced Research

Sensitivity Highly Sensitive

Download

HPLC catalogue