Home.
About.
Contact Us.
Services.
Catalogue.
Customized.
Newsletter.
FAQ.
Legal.
Free Downloads.
New products.
Contact Us

YL9110 Quaternary Pump

Operating principle: Parallel dual-plunger pump, Low-pressure gradient

Control mode: Constant flow, Constant pressure

Compressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : ≤1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi > Operating range: 0-6000 psi up to 5ml/min  > Operating range : 0-3000 psi up to 10ml/min

Pressure pulsation : ≤1% at 1ml/min

Number of eluent lines: 4

Gradient formation: 4-channel mixing valve

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection, 50/60Hz, ±5% , 70W

YL9120 UV/Vis Detector

Wavelength Range: 190-900 nm

Data collection rate: up to 50Hz

Deuterium arc lamp & tungsten lamp

2-Order filter: Automatic filter switching

Bandwidth: 5.5 nm

Wavelength Accuracy : ±1 nm

Wavelength Precision : ±0.1nm

Linearity: >99.5% at 2.5 AU (acetone, 254nm)

Noise level : <±0.5 X 10^(-5) Abs/min , 254nm, dry cell

Drift : <1 X 10^(-4) Abs/hour

Dispersion element: Concave grating

Warm-up period: 1 hour

Flow Cell Design: Cone type

Path Length: 10 mm (Analytical cell)

Cell Volume: 10 uL (Analytical cell)

Pressure limit: 1500psi (Analytical cell)

Wetted materials: 316 stainless steel, Quartz, Teflon

Analog Outputs:  Two, software selectable: Absorbance Energy, Sample Energy, Reference Energy Communications: LAN

Power-up Diagnostics: Optics and electronic diagnostic routine

Power-up Wavelength Verification: Automatic on power up via internal holmium filter and D2 lamp

5-Point Wavelength Calibration: On demand via internal holmium filter and D2 lamp

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 100W

YL9150 Autosampler (Alias)

Sound pressure level: LeAq < 70 dB

Working temperature: 10 - 40°C

Humidity: 20 - 80% RH

Safety and EMC compatibility: According to EC-directives; CSA (UL) approved

Power requirements: 95 - 240 Volt AC ± 10%; 50/60 Hz; 200VA

Sampling:

Sample capacity: 2 Micro Well Plates according to SBS standards; 96-well high/low

Loop volume: 1 - 5000 µL programmable, 10 mL loop optional

Dispenser syringe: 500 µL standard or 2500 µL for Prep option

Vial detection: Missing vial/well plate detection by sensor

Headspace pressure: Built-in compressor, but only for vials with septa

Switching time injection valve: Electrically < 100 msec

Piercing precision needle: ± 0.6mm

Wash solvent: External wash solvent bottle (bracket optional)

Wetted parts in flow path: SS316, PTFE (teflon), ETFE  (tefzel), VESPEL, PCTFE (Kel-F). Optional: PEEK

(10) Injection cycle time: < 60 sec. in all injection modes for 1 injection ≤ 100 µL including 300 µL wash / < 20 sec in partial loopfill mode for 1 injection of 10µL including 500 µL wash

Simultaneous sample injection in up to 4 HPLC  columns and parallel data treatment of four UV/VID detector signal

 

 

 

Contact us NOW for a quote

TecDev  

Download application sheet