YL9101 Vacuum Degasser
Number of channel: 4 CHs
Maximum flow rate: 10ml/min per channel
> 0-
Internal volume per channel: 925ul per channel
Materials in contact with solvent: Teflon AF, PEEK and Glass-
Safety & maintenance: Error detection
Dimensions: 385 X 80 X 565mm (width X height X depth)
Line Voltage : 100-
TecDev propose the new modular HPLC YL6100
Analytical HPLC



YL9110 Quaternary PumpPump
Operating principle: Parallel dual-
Control mode: Constant flow, Constant pressure
Compressibility compensation: Automatic
Flow range: 0.001-
Flow rate accuracy : ≤1% at 1ml/min
Flow rate precision: 0.1% RSD at 1ml/min
Maximum pressure: 6000 psi > Operating range: 0-
Pressure pulsation : ≤1% at 1ml/min
Number of eluent lines: 4
Gradient formation: 4-
Composition Precision: <0.1%
Composition Accuracy: <0.5%
Auto prime/purge
Communications: LAN
Safety & maintenance: Leak detection, Diagnostics, Error detection
Dimensions: 385 X 160 X 565mm (width X height X depth)
Line Voltage : 100-

YL9111 Binary Pump
Operating principle: X 2 Parallel dual-
Flow range: 0.001-
Number of eluent lines: 2
Communications: LAN
Safety & maintenance: Leak detection, Diagnostics, Error detection
Dimensions: 385 X 160 X 565mm (width X height X depth)
Line Voltage : 100-

.YL9112 Isocratic Pump
Operating principle: Parallel dual-
Compressibility compensation: Automatic
Flow range: 0.001-
Flow rate accuracy : ≤1% at 1ml/min
Flow rate precision: 0.1% RSD at 1ml/min
Maximum pressure: 6000 psi
> Operating range: 0-
> Operating range: 0-
Pressure pulsation : ≤1% at 1ml/min
Composition Precision: <0.1%
Composition Accuracy: <0.5%
Auto prime/purge
Communications: LAN
Safety & maintenance: Leak detection, Diagnostics, Error detection
Dimensions: 385 X 160 X 565mm (width X height X depth)
Line Voltage : 100-

YL9120 UV/Vis Detector
Wavelength Range: 190-
Data collection rate: up to 50Hz
Deuterium arc lamp & tungsten lamp
2-
Bandwidth: 5.5 nm
Wavelength Accuracy : ±1 nm
Wavelength Precision : ±0.1nm
Linearity: >99.5% at 2.5 AU (acetone, 254nm)
Noise level : <±0.5 X 10^(-
Drift : <1 X 10^(-
Dispersion element: Concave grating
Warm-
Flow Cell Design: Cone type
Path Length: 10 mm (Analytical cell)
Cell Volume: 10 uL (Analytical cell)
Pressure limit: 1500psi (Analytical cell)
Wetted materials: 316 stainless steel, Quartz, Teflon
Analog Outputs: Two, software selectable: Absorbance Energy, Sample Energy, Reference Energy Communications: LAN
Power-
Power-
5-
Safety & maintenance: Leak detection, Diagnostics, Error detection
Dimensions: 385 X 160 X 565mm (width X height X depth)
Line Voltage : 100-

YL9160 PDA Detector
PDA A/D Resolution: 16bit
Slit Bandwidth: 1.7nm Pixel Resolution: 0.9nm Channel: 1024
Wavelength: 190~950
Shield Optics
Analytical Cell
-
-
-
Dimension: W: 385mm H: 160mm D: 565mm
Weight: 15Kg
Noise Level: +/-
Drift : 0.0002AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)
Wavelength Accuracy: <1nm (HY-
Sampling Rate: Max. 50Hz 1~16 nm Spectral Bandwidth, Wide Spectral Range, Alternative Spectral Function
GLP Compliance:
-
-
Analog Output: 2 channel (Replaceable Dual Wavelength Detector)
Valve Output: 2ch, Programmable Sampling (Fraction Collector Function Available )
Trigger Input: 2ch
Communication: TCP/IP, RS232C
Simultaneous Data Channel: 8 or Full Scan
Filtering: Bessel, RC, Aver. 0.01~10Hz

YL9150 Autosampler (Alias)
Sound pressure level: LeAq < 70 dB
Working temperature: 10 -
Humidity: 20 -
Safety and EMC compatibility: According to EC-
Power requirements: 95 -
Sampling:
Sample capacity: 2 Micro Well Plates according to SBS standards; 96-
Loop volume: 1 -
Dispenser syringe: 500 µL standard or 2500 µL for Prep option
Vial detection: Missing vial/well plate detection by sensor
Headspace pressure: Built-
Switching time injection valve: Electrically < 100 msec
Piercing precision needle: ± 0.6mm
Wash solvent: External wash solvent bottle (bracket optional)
Wetted parts in flow path: SS316, PTFE (teflon), ETFE (tefzel), VESPEL, PCTFE (Kel-
(10) Injection cycle time: < 60 sec. in all injection modes for 1 injection ≤ 100 µL including 300 µL wash / < 20 sec in partial loopfill mode for 1 injection of 10µL including 500 µL wash

Why purchase a HPLC twice the price you can get it at TecDev ?
YL-
Direct control of YL9100 HPLC.
Measuring: Simultaneous data acquisition from up to four independent chromatographs, each chromatograph can acquire data from up to 12 detectors.
Integration: There is extensive possibility to modify chromatograms. The chromatogram can be changed by entering global parameters or interactively, through direct graphic modification of the baseline.
Overlay: Simultaneously displays a virtually unlimited number of chromatograms and their mathematical modification; for example, mutual deductions or derivations of any order.
Calibration: Internal and external standard calculation methods, calibration of groups of peaks and reference peaks method for better identification.
Automated measuring support: Sequence tables for any set of samples with or without an autosampler.
Post-
Summary result tables: Displays and prints selected results from all simultaneously displayed chromatograms.
User settings: User selects parameters for peak display and the specification for axes, including color from an extensive array of color settings. Text labels and lines, either as part of the area or anchored to a chromatogram, may also be inserted.
Export: Optional exportation of all results, with or without the chromatogram, in various formats, into a file or clipboard.
Import: Imports chromatograms or mathematical curves, which have been saved in text or AIA formats, from other programs.
Method and calibration history: Each chromatogram can easily be displayed under the same conditions as when it was printed, exported or saved.
Column performance: Calculations of peaks in terms of symmetry, efficiency, resolution; all by several methods (tangent, moments, etc.).
Batch: Automatically batch processes, displays, exports or prints any number of chromatograms.
User calculations: Users can define custom calculations in the Result and Summary tables. Using the integrated editor you can create your own columns from original columns and individual mathematical functions.
User accounts: Sets up access rights and passwords (including their parameters e.g., minimum length, validity, etc.). Each user can define his or her own station appearance.
Audit trail: Records selected events and operations into a special file. Records selected operations directly into a chromatogram.
Electronic signature: Each chromatogram can be signed electronically. Signature selection is based on the username or the signature certificate.
Networked Solution: Clarity chromatography station files can be accessed from networked computers using Clarity software. This enables the offline evaluation of chromatograms, development of new methods and printing reports.
21 CFR Part 11: Clarity Satisfies with the requirements of the 21 CFR Part 11 directive of the FDA.
Operating Windows: Microsoft Window 2000, XP and Vista (32 bit)


Same performance, better price
What is your choice tomorrow?