YL9101 Vacuum Degasser

Number of channel: 4 CHs

Maximum flow rate: 10ml/min per channel

> 0-2.0ml/min per channel for 70% Gas Removed from Methanol

Internal volume per channel: 925ul per channel

Materials in contact with solvent: Teflon AF, PEEK and Glass-filled PTFE

Safety & maintenance: Error detection

Dimensions: 385 X 80 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection; 50/60Hz, ±5%, 20W

wpffabd1f7.gif
wpffabd1f7.gif
wpffabd1f7.gif
wpffabd1f7.gif
wpffabd1f7.gif











TecDev  propose the new  modular HPLC  YL6100

                        

                         Analytical  HPLC

                        

 

wpe9d8efe0.png
wpab2201f3.png
wp9a6e4388.png
wpd1926b1e.png

YL9110 Quaternary PumpPump

Operating principle: Parallel dual-plunger pump, Low-pressure gradient

Control mode: Constant flow, Constant pressure

Compressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : 1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi > Operating range: 0-6000 psi up to 5ml/min  > Operating range : 0-3000 psi up to 10ml/min

Pressure pulsation : 1% at 1ml/min

Number of eluent lines: 4

Gradient formation: 4-channel mixing valve

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, automatic voltage selection, 50/60Hz, ±5% , 70W

 

wp94093250.png

YL9111 Binary Pump

Operating principle: X 2 Parallel dual-plunger pump, High-pressure gradient

Flow range: 0.001-10ml/min

Number of eluent lines: 2

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 140W

 

wpe09a8998.png

.YL9112 Isocratic Pump

Operating principle: Parallel dual-plunger pump

Compressibility compensation: Automatic

Flow range: 0.001-10ml/min

Flow rate accuracy : 1% at 1ml/min

Flow rate precision: 0.1% RSD at 1ml/min

Maximum pressure: 6000 psi

> Operating range: 0-6000 psi up to 5ml/min

> Operating range: 0-3000 psi up to 10ml/min

Pressure pulsation : 1% at 1ml/min

Composition Precision: <0.1%

Composition Accuracy: <0.5%

Auto prime/purge

Communications: LAN

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%,  50/60Hz, ±5%, 70W

 

wp3751d11f.png

YL9120 UV/Vis Detector

Wavelength Range: 190-900 nm

Data collection rate: up to 50Hz

Deuterium arc lamp & tungsten lamp

2-Order filter: Automatic filter switching

Bandwidth: 5.5 nm

Wavelength Accuracy : ±1 nm

Wavelength Precision : ±0.1nm

Linearity: >99.5% at 2.5 AU (acetone, 254nm)

Noise level : <±0.5 X 10^(-5) Abs/min , 254nm, dry cell

Drift : <1 X 10^(-4) Abs/hour

Dispersion element: Concave grating

Warm-up period: 1 hour

Flow Cell Design: Cone type

Path Length: 10 mm (Analytical cell)

Cell Volume: 10 uL (Analytical cell)

Pressure limit: 1500psi (Analytical cell)

Wetted materials: 316 stainless steel, Quartz, Teflon

Analog Outputs:  Two, software selectable: Absorbance Energy, Sample Energy, Reference Energy Communications: LAN

Power-up Diagnostics: Optics and electronic diagnostic routine

Power-up Wavelength Verification: Automatic on power up via internal holmium filter and D2 lamp

5-Point Wavelength Calibration: On demand via internal holmium filter and D2 lamp

Safety & maintenance: Leak detection, Diagnostics, Error detection

Dimensions: 385 X 160 X 565mm (width X height X depth)

Line Voltage : 100-240VAC, ±10%, 50/60Hz, ±5%, 100W

wp746aeafd.png

YL9160 PDA Detector

PDA  A/D Resolution: 16bit

Slit Bandwidth:  1.7nm  Pixel Resolution: 0.9nm Channel: 1024

Wavelength: 190~950

Shield Optics

Analytical Cell

     - Path-length: 10mm

     - Pressure       : >1500psi

     - Volume         : 13ul

Dimension:   W: 385mm  H: 160mm  D: 565mm

Weight:  15Kg

Noise Level: +/- 0.00002 AU (Empty Cell, 1sec Rise Time, 254nm)  

Drift  : 0.0002AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)

 

Wavelength Accuracy: <1nm (HY-1 Holmium Oxide Filter)

 

Sampling Rate: Max. 50Hz  1~16 nm Spectral Bandwidth, Wide Spectral Range, Alternative Spectral Function

 

GLP Compliance:

 - Photometric Accuracy, Linearity, Noise Level, Drift

       - System Check,

 

Analog Output: 2 channel (Replaceable Dual Wavelength Detector)      

Valve Output:  2ch, Programmable Sampling (Fraction Collector Function Available )

 

Trigger Input: 2ch

Communication: TCP/IP, RS232C

Simultaneous Data Channel:  8 or Full Scan

Filtering: Bessel, RC, Aver. 0.01~10Hz

wpef86b8f6.png

YL9150 Autosampler (Alias)

Sound pressure level: LeAq < 70 dB

Working temperature: 10 - 40°C

Humidity: 20 - 80% RH

Safety and EMC compatibility: According to EC-directives; CSA (UL) approved

Power requirements: 95 - 240 Volt AC ± 10%; 50/60 Hz; 200VA

Sampling:

Sample capacity: 2 Micro Well Plates according to SBS standards; 96-well high/low

Loop volume: 1 - 5000 µL programmable, 10 mL loop optional

Dispenser syringe: 500 µL standard or 2500 µL for Prep option

Vial detection: Missing vial/well plate detection by sensor

Headspace pressure: Built-in compressor, but only for vials with septa

Switching time injection valve: Electrically < 100 msec

Piercing precision needle: ± 0.6mm

Wash solvent: External wash solvent bottle (bracket optional)

Wetted parts in flow path: SS316, PTFE (teflon), ETFE  (tefzel), VESPEL, PCTFE (Kel-F). Optional: PEEK

(10) Injection cycle time: < 60 sec. in all injection modes for 1 injection ≤ 100 µL including 300 µL wash / < 20 sec in partial loopfill mode for 1 injection of 10µL including 500 µL wash

 

wp001cef30.png

Why purchase a HPLC twice the price you can get it at TecDev  ?

YL-Clarity Data System

 

Direct control of YL9100 HPLC.

Measuring: Simultaneous data acquisition from up to four independent chromatographs, each chromatograph can acquire data from up to 12 detectors.

Integration: There is extensive possibility to modify chromatograms. The chromatogram can be changed by entering global parameters or interactively, through direct graphic modification of the baseline.

Overlay: Simultaneously displays a virtually unlimited number of chromatograms and their mathematical modification; for example, mutual deductions or derivations of any order.

Calibration: Internal and external standard calculation methods, calibration of groups of peaks and reference peaks method for better identification.

Automated measuring support: Sequence tables for any set of samples with or without an autosampler.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Post-run: Automatically displays, prints, exports and starts other programs after the completion of a measurement.

Summary result tables: Displays and prints selected results from all simultaneously displayed chromatograms.

User settings: User selects parameters for peak display and the specification for axes, including color from an extensive array of color settings. Text labels and lines, either as part of the area or anchored to a chromatogram, may also be inserted.

Export: Optional exportation of all results, with or without the chromatogram, in various formats, into a file or clipboard.

Import: Imports chromatograms or mathematical curves, which have been saved in text or AIA formats, from other programs.

Method and calibration history: Each chromatogram can easily be displayed under the same conditions as when it was printed, exported or saved.

Column performance: Calculations of peaks in terms of symmetry, efficiency, resolution; all by several methods (tangent, moments, etc.).

 

Batch: Automatically batch processes, displays, exports or prints any number of chromatograms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User calculations: Users can define custom calculations in the Result and Summary tables. Using the integrated editor you can create your own columns from original columns and individual mathematical functions.

User accounts: Sets up access rights and passwords (including their parameters e.g., minimum length, validity, etc.). Each user can define his or her own station appearance.

Audit trail: Records selected events and operations into a special file. Records selected operations directly into a chromatogram.

Electronic signature: Each chromatogram can be signed electronically. Signature selection is based on the username or the signature certificate.

Networked Solution: Clarity chromatography station files can be accessed from networked computers using Clarity software. This enables the offline evaluation of chromatograms, development of new methods and printing reports.

21 CFR Part 11: Clarity Satisfies with the requirements of the 21 CFR Part 11 directive of the FDA.

Operating Windows: Microsoft Window 2000, XP and Vista (32 bit)

 