Free to choose your reagents,

the best choice for your clinical laboratory

Easy keypad operation with LCD display

Wavelengths range is 330-800nm, 5 standard filters, 3 more filters optional

Reagent open system supports flow cell and cuvette mode, close system on request

Analytical modes include kinetic, fixed time, bichromatic end point with or without

reagent blank or sample blank, linear or non-linear calibration curves

Up to 60 programs and 2200 test results can be stored

Excellent QC function,2 controls per test

Internal thermal-sensitive printer

Compact design enables USER-DIY maintenance

Multi-language software available on request

 

Technical Specifications:

Absorbance Range: -0.500 - 3.500Abs

Resolution:  0.001 Abs (displayed), 0.0001Abs (calculated)

Light Source: Halogen lamp, 12V/20W

Wavelengths: 340, 405, 500, 546, 620nm, 3 more filters optional

Wavelength Accuracy: ± 1nm    Band Width:  < 8nm

Flow Cell:  Metal - quartz flow cell

Temperature Control: 25,30,37degre C , ±0.1degre C and ambient temperature

Carryover: < 1%

Display: LCD display

Interface: RS-232  Output:    Internal and external printer (optional)

Power Supply:  AC 100V - 240V ± 10%, 50-60Hz

Net Weight:  7Kg

Dimensions Dimensions L × W × H (mm): 370 x 284 x 318

RT-9200 Semi-Auto Chemistry Analyzer

RT-9600 Semi-Auto Chemistry Analyzer

Home.
About.
Contact Us.
Services.
Catalogue.
Customized.
Newsletter.
FAQ.
Legal.
Free Downloads.
New products.

Easy Windows operation system with large touch-screen

Displays the reaction curve in real-time

Continuously adjustable grating, enhances the stability and reliability of result

Reagent-open system supports flow cell and cuvette mode, close system on request

Analytical modes include kinetic, fixed time, bichromatic end point with or without

reagent blank or sample blank, linear or non-linear calibration

Large memory, up to 200 test protocols and 10000 results can be stored, compatible with SD card

Powerful QC program: Westguard multi-rule, Levey-Jennings plots,2 controls per test

Multiform result output including patient comprehensive report

Multi-interface support RS-232,VGA,USB,SD and Ethernet

Easy communication with PC

Powerful internet connection enables remote data sharing and OS update

Compact design enables USER-DIY maintenance

Multi-language software available on request

 

Absorbance Range:  -0.500 - 3.500Abs

Resolution: 0.001 Abs (displayed), 0.0001Abs (calculated)

Light Source: Halogen lamp, 12V/20W

Wavelengths: Continuously adjusted grating, wavelength range is 330 - 800nm, 1nm by step adjustment

Wavelength Accuracy: ± 1nm  Band Width < 6nm

Flow Cell: Metal - quartz flow cell

Temperature Control: 25,30,37degre C , ±0.1degre C and ambient temperature

Carryover.< 1%

Memory: 200 test protocols, up to 10000 test results, support SD to expand memory

Display: 6.4" color/mono LCD

Output: Built-in printer or external printer Input: Touch screen, mouse and keyboard optional

Interface: RS-232,support VGA,2 USB, SD, Ethernet

Language: English or any language on request

Power Supply: AC 100V - 240V ± 10%,50-60Hz

Net Weight: 11KG

Dimensions L xW xH (mm): 370 x 284 x 318

RT-200C PLUS Auto Chemistry Analyzer           !!   Same analyzer available  for on bench installation  !!

Simplicity of operation and flexibility with user friendly software under Windows OS

Reagent open system, close system on request

Stable throughput with reliable results, cost effective

STAT sample priority enabled

Liquid level detection for sample and reagent probes

Dual reagent assay supported with mixer

Air/Water rinse flow cell, auto/manual rinse, low carryover

Analytical modes including Multi-stand, Fixed time, End-point and Kinetic

Built-in QC Management and Multi-form report output

Large memory, up to 1 million patients' data can be stored and unlimited programs defined

Compact design gives ease in maintenance, Slave analyzer available to get higher throughput

Multi-language software available on request

Automatic, STAT Available

Throughput: Up to 200 tests/hour

Method: End-point, Kinetic, Fixed time, Single/Dual Reagent , Monochromatic, Bichromatic, Linear /non-linear multipoint calibration

Quality Control: QC calculation monthly Calibration Mode: One point/ multi-point, log, exponential, polynomial, parabola

Memory: 80 G

Light Source:Halogen lamp Wavelengths: 8 filters including 340nm, 405nm, 492nm, 510nm, 535nm, 546nm, 578nm, 620nm

Absorbance Range: 0-3.000Abs ± 1%

Resolution:  0.0005Abs

Operation System: Windows

Display: 15'' color LCD or CRT

Interface: RS-232

Sample Position: 60 positions Sample Volume: 3-500μl (>5 μl is recommended), 1μl increment  Sample Probe Liquid level detection

Reagent Position. 36 positions, refrigerated Reagent Volume:  200-500μl, 1μl increment Reagent Probe Liquid level detection

Reaction Position:  120 positions Reaction Volume: 300-500μL

Operation Temperature: 25°C,30°C,37°C, Room temperature Temperature Regulation: ±0.1°C

Power Supply: AC 200V - 240V ± 10%,50-60Hz

Dimensions(Floor standing) L×W×H(mm): 872×720×1069

NEW
NEW
NEW

>98% Correlation to Modified Westergren Method

Provides accurate results in only 30 minutes (15-minute prediction

mode). Ensures confidence and saves time and money.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Internal Printer

Automatically prints patient results at the conclusion of the test.

Eliminates repeat testing and saves valuable benchtop space.

Full Random Access

Eliminates sample batching and provides flexibility. Ten-sample

capacity allows patient testing at your convenience.

Positive Sample Identification

Barcode scanner aids in patient sample indentification and prevents

transcription errors. Stores patient results in log file.

QC Data Storage

Stores lot-specific QC information for up to 100 runs of QC data

per level.

LIS Compatible

An LIS interface prevents transcription errors and aids in patient

sample identification.

72-Hour Patient Sample Stability

ESR-Vacuum Tubes preserve the integrity of the patient sample for

up to 72 hours at 2-10° C. Ensures specimen stability during transit

from off-site blood collection facility.

Closed Blood Collection System

Reduces exposure to potentially hazardous material. Allows direct

vacuum blood collection or transfer from an EDTA (purple-top)

tube.

Complete System

The ESR-10 Manual Rack is a 30-minute manual system that uses

Streck ESR-Vacuum Tubes. Safety-coated tubes and ESR-Chex

control are available, as well as an ESR placement program.

Excellent Service

TecDev provides superior sales, customer and technical service to

help you through the ordering and evaluation process. The ESRAuto

Plus has a proven track record and substantial peer group.