AQF-2100  Automated sample mineralisation

for solid and liquid samples

Automation for halogen and sulfur analysis in complex samples using an IC system

 

The AQF-2100 is a completely  unique instrument for qualitative and quantitative measurement of all halogens and sulfur  in practically  any kind of samples.

 

Method  compatibility

D5987  - Fluorine in Coal and Coke

D7359  - Sulfur, Chlorine and Fluorine in Aromatic Hydrocarbon

JEITA    - (Japan Electronics and Information Technology Industries Association)

ET-7304 - Chlorine, Fluorine, Bromine (Halogen Free) in Soldering Materials

This instrument can replace all the mineralisation systems (Oxygen  bomb, microwave high pressure mineralisation) and , in conjunction with a Ion Chromatography system  allow total automation in the analysis of complex samples, industrial  residue, solvent mixes, soil samples, resin, wood  etc...  Save time , increase performance, increase throughput, cut your analysis cost with this unique instrument.

 

 

New features:

 

Full automation from calibration to shut down.

A single combustion method for unknown sample.

Open/close furnace for check and maintenance.

Ability of upgrade up to 4 detectors in one furnace

Integrated hydropyrolysis function.

Other analyzers can be utilized (ICP-MS/AES, AA).

 

Analysis method:                              Oxidative decomposition, Ion Chromatography (not provided)

Combustion:                                      Pyrolysis tube silica tube combustion

Combustion furnace temperature:  1100 °C  maximum

Samples to analyze:                         Liquid, solid and gaseous samples(with special sampling device)

Enrichment  method:                        Using trapping solution , multi enrichment possible

Amount of samples to measure:     Solid: up to 1-100 mg;  Liquid: 1 to 100 µl  ; Gas: 1 to 10 ml

Measurement range:                        depending on IC system, compatible with Metrohm IC and  Dionex IC Measurement accuracy check:       Using internal standard                          

Measurement time:                          Approx. 10-15 min./sample depending on IC method, including sample injection and                                                                             mineralisation

Interface:                                           1 channel for PC input/output (RS232C)

Instrument control and Data processing: Via PC software, application data bank, export functions, QC Check  functions

 

Gas used:

Argon: Purity greater than 99.98%, 300±100 kPa

Oxygen: Purity greater than 99.7%, 300±100 kPa

Home.
About.
Contact Us.
Services.
Catalogue.
Customized.
Newsletter.
FAQ.
Legal.
Free Downloads.
New products.

 

Liquid Sample Changer  ASC-250L

50 liquid samples

100 ul injection

2,4,6 ml sample vial

Solid Sample Changer  ASC-240S

40 solids, 100mg.

Manual liquid, 100ul.

Safety sensor.

Gas Injector  GI-220

25 -100ml gas.

Auto syringe pump.

Configurable inj. speed.

Safe for flammable gas   handling

Gas Injector GI-210

10ml gas.

Safe for flammable gas handling

Optional module

Chlorine

Bromine

Iodine

Fluorine

Sulfur

Download

AQF 2100 catalogue