AQF-2100 Automated sample mineralisation
for solid and liquid samples
Automation for halogen and sulfur analysis in complex samples using an IC system
The AQF-2100 is a completely unique instrument for qualitative and quantitative measurement of all halogens and sulfur in practically any kind of samples.
Method compatibility
D5987 - Fluorine in Coal and Coke
D7359 - Sulfur, Chlorine and Fluorine in Aromatic Hydrocarbon
JEITA - (Japan Electronics and Information Technology Industries Association)
ET-7304 - Chlorine, Fluorine, Bromine (Halogen Free) in Soldering Materials
This instrument can replace all the mineralisation systems (Oxygen bomb, microwave high pressure mineralisation) and , in conjunction with a Ion Chromatography system allow total automation in the analysis of complex samples, industrial residue, solvent mixes, soil samples, resin, wood etc... Save time , increase performance, increase throughput, cut your analysis cost with this unique instrument.
New features:
Full automation from calibration to shut down.
A single combustion method for unknown sample.
Open/close furnace for check and maintenance.
Ability of upgrade up to 4 detectors in one furnace
Integrated hydropyrolysis function.
Other analyzers can be utilized (ICP-MS/AES, AA).
Analysis method: Oxidative decomposition, Ion Chromatography (not provided)
Combustion: Pyrolysis tube silica tube combustion
Combustion furnace temperature: 1100 °C maximum
Samples to analyze: Liquid, solid and gaseous samples(with special sampling device)
Enrichment method: Using trapping solution , multi enrichment possible
Amount of samples to measure: Solid: up to 1-100 mg; Liquid: 1 to 100 µl ; Gas: 1 to 10 ml
Measurement range: depending on IC system, compatible with Metrohm IC and Dionex IC Measurement accuracy check: Using internal standard
Measurement time: Approx. 10-15 min./sample depending on IC method, including sample injection and mineralisation
Interface: 1 channel for PC input/output (RS232C)
Instrument control and Data processing: Via PC software, application data bank, export functions, QC Check functions
Gas used:
Argon: Purity greater than 99.98%, 300±100 kPa
Oxygen: Purity greater than 99.7%, 300±100 kPa


Liquid Sample Changer ASC-250L
50 liquid samples
100 ul injection
2,4,6 ml sample vial
Solid Sample Changer ASC-240S
40 solids, 100mg.
Manual liquid, 100ul.
Safety sensor.
Gas Injector GI-220
25 -100ml gas.
Auto syringe pump.
Configurable inj. speed.
Safe for flammable gas handling
Gas Injector GI-210
10ml gas.
Safe for flammable gas handling



Optional module
Chlorine
Bromine
Iodine
Fluorine
Sulfur
Download
AQF 2100 catalogue